Leak Detection Oil Hot Water Boiler 1.1 - 22 KW/H Electric Consumption

Brand Name : LEWAY BOILER

Model Number : CWNS

Certification : SGS, ISO, OHSAS

Place of Origin : Henan, China (Mainland)

MOQ : 1

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 300 Ton/Tons per Month hot water boiler

Delivery Time : Average 15 Days

Packaging Details : PE films for oil hot water boiler main body; plywood boxes for all auxiliaries

Rated Power : 0.35MW-7MW

Condition : New

Type : Natural Circulation

Usage : Industrial

Structure : Fire Tube

Pressure : Atmospheric Pressure

Material : Special Boiler Steel Plate

After-sales Service Provided : Engineers available to service machinery overseas

Contact Now

Engineers Available To Service Machinery Overseas Oil Hot Water Boiler

Product Description
Product Name

Oil Hot Water Boiler

Fuel Type
Diesel,Heavy Oil,Crude Oil
Thermal Efficiency

95%

Operation Control

PLC Programmable Control

After-sales Service Provided

Engineers Available To Service Machinery Overseas

Features

1. Applied international latest technology for big volume combustion room design, and use Italy combustion machine.

2. Corrugated furnace design make large heat transfer area and protect furnace.

3. Using fire-tube with screw thread, 1-2 faster heat transfer efficiency and remove hidden danger of welding cracks.

4. Wet-back boiler reduce faults rate and maintenance cost.

5. With protection devices for overheating, overpressure, lacking water, leak detection, flameout etc.

Quality Assurance

1. Strength calculation test report of applied materials

2. Whole set of pure water processor line featured with RO anti-saturation and advanced testing devices

3. Hydraulic test report: ensure the standard working pressure and safety

4. Third-party inspection report-Jiaozuo Special Equipment Inspection & Technical Research

Hot Water Boiler Model

Item / Unit / Model

CWNS

0.35- 85/65-Y(Q)

CWNS

0.48- 85/65-Y(Q)

CWNS

0.58-85/65-Y(Q)

CWNS

0.7- 85/65-Y(Q)

CWNS 1.05-85/65- Y(Q) CWNS 1.4-85/65-Y(Q) CWNS 2.1-85/65-Y(Q) CWNS 2.8-85/65-Y(Q) CWNS 4.2-85/65-Y(Q) CWNS 5.6-85/65-Y(Q) CWNS 7.0-85/65-Y(Q)

Rated Heat Capacity

MW 0.35 0.48 0.58 0.7 1.05 1.4 2.1 2.8 4.2 5.6 7.0
Working Pressure MPa Non Pressure

Inlet/Outlet Water

Temperature

85/65 85/65 85/65 85/65 85/65 85/65 85/65 85/65 85/65 85/65 85/65

Heating Surface

19.5 21 31 34.2 50.2 65.76 93.61 113.44 187.1 260.36 273.7

Thermal Efficiency

% 91-98%
Fuel Consumption Natural Gas Nm³/h 36/38 49/52 59/63 71/76.7 104/112 142/153.4 208/226.1 280/304.8 414/440.3 547/602.5 680/730
Diesel Kg/h 32.5 44.5 53.8 64.9 97.4 139.9 194.8 259.8 376.5 497.6 623.7

Electric

Consumption

KW/h 1.1 2.3 2.3 2.3 4.0 4.7 7.5 8.2 11 15 22
Transport Weight Kg 1550 1650 1950 2100 2900 3500 4950 5190 10600 16000 19104
Water Volume L 700 850 1100 1500 1848 2700 3600 5000 9000 13300 13300
Dimension Length mm 2260 2280 2395 2695 3205 3685 3915 4415 5300 6420 6822
Width mm 1120 1120 1475 1475 1475 1665 1750 1900 2380 2528 2550
Height mm 1550 1590 1750 1750 1750 2015 2160 2300 2742 3015 3064

Water Outlet Pipe

mm 80 80 100 100 125 150 150 200 200 250 250
Water Inlet Pipe mm 80 80 100 100 125 150 150 200 200 250 250
Atmosphere Open Pipe mm 80 80 100 100 125 150 150 200 200 250 250
Drain Pipe mm 40 40 40 40 40 40 40 40 40 40 40
Chimney mm 250 250 250 250 250 300 350 400 600 700 800
Basement Dimensions Length mm 1950 1980 2050 2120 2620 3100 3100 3560 4100 5200 5380
Width mm 800 810 1000 1000 1000 1100 1200 1300 1750 2000 2100

Our Services

Pre-sale service:
Accept inquiry of customers ,confirmation of investment advice of choice of product ,assist the customers to design the workshop.

In-sale service:
Help customers finish the basal equipment ,technical training of customers’s workers ,practice of operation ,help to install ,train the operators in the workshop.

After-sale service:
24 hours service of technology inquiry, instant components supply, regularly technical service guidance of maintain,long distance malfunction control.

Unique service:
System up-grade,special design according to the customers’ requirement, mould renew, supply new technology and products information.

Leak Detection Oil Hot Water Boiler 1.1 - 22 KW/H Electric Consumption


Product Tags:

oil hot water furnace

      

oil fired water boiler

      
China Leak Detection Oil Hot Water Boiler 1.1 - 22 KW/H Electric Consumption wholesale

Leak Detection Oil Hot Water Boiler 1.1 - 22 KW/H Electric Consumption Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Henan Leway Thermal Equipment Manufacture Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2024 hardware-wholesale.com. All rights reserved.